• videomancer/1.0.2-rc.4 227630556a

    lars released this 2026-10-22 21:57:43 +00:00 | 0 commits to main since this release

    Videomancer 1.0.2-rc.4

    Fourth release candidate for 1.0.2. Everything from 1.0.2-rc.3 is carried over;
    this candidate makes every modulation Gain and Depth knob a bipolar
    attenuverter. Flash the full UF2; program library 1.0.10 and LZX Connect
    1.3.10 or newer still apply.

    Changed since 1.0.2-rc.3

    • Gain and Depth are attenuverters — on every modulation operator where
      the M2 knob reads Gain or Depth, center is now null, right applies the
      modulation as before, and left applies the same amount inverted. The
      display reads −100 to 100. Fully right is the same 1× gain the knob had at
      100%; fully left is −1×. Folds (Wavefolder), Prob (Prob Gate) and Release
      (Keyboard) are not gains and keep their 0–100 range.
    • Toggle targets — a negative Gain or Depth inverts the gate. At center,
      the toggle stays where its Manual position puts it.
    • Saved presets keep their amount — user presets now save as format v3.
      Presets saved on earlier firmware load with each Gain/Depth moved onto the
      positive half (old 0% = center, 50% = +50, 100% = +100), so they sound the
      same.
    • Reset starts at null — after resetting all modulators, Gain/Depth sits
      at center, which now means no modulation (it used to mean 50%). Turn it
      right to hear the operator.

    Carried from 1.0.2-rc.3

    • Streamed program loads (Upload Program) report fpga_config_timeout and
      step the SPI clock down on the next try; the configuration clock resets
      after a retry.
    • fs put streams at line rate; library installs right after power-on no
      longer time out. Picker author scan shows Scanning n/m; MIDI Assign only
      opens on a held P switch.

    Over USB

    • Modulator space values and the sp: field of program presets save use
      the new meaning: 512 is null, 0 is full inverted, 1023 is full positive.
      Presets written by a host tool in the old 0–100% meaning are not converted.

    Status

    • Builds clean in the desk WSL build; host test suite passes, including new
      checks for center null, inverted swing, toggle inversion and preset
      conversion.
    • Not yet run on the desk unit. Beta testers: please try Gain/Depth on an
      LFO and on a CV Input, and load a preset saved on rc.3 or earlier.

    Requires

    • Flash 1.0.2-rc.4 UF2 (full image).
    • LZX Connect 1.3.10 or newer; 1.3.13 resends Upload Program
      automatically on a configuration failure.
    • Turn on Show pre-releases in Connect to see this candidate.

    Report feedback at /instruments/videomancer/beta.

    Downloads