• videomancer/1.0.2-rc.1 227630556a

    lars released this 2026-10-20 19:59:47 +00:00 | 0 commits to main since this release

    Release videomancer/1.0.2-rc.1 for VIDEOMANCER-FIRMWARE.

    InvenTree

    Created by LZX Actions tag_released automation.

    Downloads
  • videomancer/1.0.1 227630556a

    lars released this 2026-10-18 05:27:41 +00:00 | 0 commits to main since this release

    Release videomancer/1.0.1 for VIDEOMANCER-FIRMWARE.

    InvenTree

    Created by LZX Actions tag_released automation.

    Downloads
  • programs/1.0.10 227630556a

    lars released this 2026-10-18 05:27:30 +00:00 | 0 commits to main since this release

    Release programs/1.0.10 for VIDEOMANCER-FIRMWARE.

    InvenTree

    Created by LZX Actions tag_released automation.

    Downloads
  • connect/1.3.11 227630556a

    lars released this 2026-10-13 21:07:35 +00:00 | 0 commits to main since this release

    Release connect/1.3.11 for VIDEOMANCER-FIRMWARE.

    InvenTree

    Created by LZX Actions tag_released automation.

    Downloads
  • programs/1.0.9 227630556a

    lars released this 2026-10-13 01:41:26 +00:00 | 0 commits to main since this release

    Release programs/1.0.9 for VIDEOMANCER-FIRMWARE.

    InvenTree

    Created by LZX Actions tag_released automation.

    Downloads
  • videomancer/1.0.0 227630556a

    lars released this 2026-10-13 01:41:13 +00:00 | 0 commits to main since this release

    Release videomancer/1.0.0 for VIDEOMANCER-FIRMWARE.

    InvenTree

    Created by LZX Actions tag_released automation.

    Downloads
  • connect/1.3.10 227630556a

    lars released this 2026-10-11 23:46:43 +00:00 | 0 commits to main since this release

    LZX Connect 1.3.10

    Bugfix release: program library installs no longer blame a write-protected card when the device resets mid-mkdir.

    Fixed in 1.3.10

    • Slow SD commands — fs stat and fs mkdir wait 5 seconds, matching the firmware window used while a card is busy
    • Error messages — A USB disconnect during library folder creation no longer adds a write-protect hint

    Requires Videomancer firmware

    Creating program folders on a slow card needs Videomancer 1.0.0-rc.70 or later. Until that firmware is installed, create programs/lzx/ (and each community author folder) from USB storage mode, eject, power-cycle, and retry the install.

    Supported devices

    • Videomancer (UF2)
    • Scrolls, Diver, Escher Sketch (STM32 DFU)
    • TBC2 Mk2, Memory Palace (USB mass storage)

    Artifacts

    • Windows: MSI + NSIS setup
    • macOS: universal DMG (Apple Silicon + Intel)
    • Linux: .deb + AppImage
    Downloads
  • videomancer/1.0.0-rc.70 227630556a

    lars released this 2026-10-11 20:10:53 +00:00 | 0 commits to main since this release

    Release videomancer/1.0.0-rc.70 for VIDEOMANCER-FIRMWARE.

    InvenTree

    Created by LZX Actions tag_released automation.

    Downloads
  • videomancer/1.0.0-rc.69 227630556a

    lars released this 2026-10-11 01:10:07 +00:00 | 0 commits to main since this release

    Videomancer 1.0.0-rc.69

    Every modulation operator that reads the rear jacks now follows one signal
    contract. Nothing patched adds nothing, 1 V at Gain 100% covers the full range,
    Audio In follows loudness, and all time knobs share one Off-to-5 s curve. This is
    the 1.0.0 candidate for audio and CV modulation.

    Changes

    • One capture per field — All four jacks are sampled at 40 kHz. CV operators
      read the newest 0.4 ms at each field; Audio In and Peak Hold read the whole
      field, so short hits between fields are never missed.
    • CV is bipolar — 0 V (or nothing patched) adds nothing and the parameter
      rests at Manual. Positive voltage moves it up, negative down. 1 V at Gain 100%
      is the full range; a ±25 mV dead zone hides jack offset. Gain is linear to
      100% (was up to 4×).
    • Audio In — Follows loudness (half the field's peak-to-peak swing, minus a
      20 mV floor). Attack is instant; Time is Release. A 0.5 V peak reaches full
      range at Gain 100%. Ch1+2 and Ch3+4 average the two levels so stereo never
      cancels.
    • Audio Follower retired — Presets that used it load as Audio In on Ch1+2,
      keeping its Release and Gain.
    • Shared time curve — Slew, Release, Decay, Rise, and Fall read Off at fully
      counter-clockwise, then 5ms to 5.00s. Peak Hold Decay reads Hold at
      maximum. Times match on per-line and field-rate slots.
    • Slew Limiter — Linear rate limit of 1 V per Rise/Fall time. Direction is
      reversed from rc.68
      : counter-clockwise is now instant.
    • Per-line operators — Comparator, Ring Mod, Peak Hold, and Quantizer on
      P1–P6 and P12 draw the previous field down the frame (slice mean, product mean,
      or max per scanline). CV Input and Audio In are field-rate on every slot.
    • Comparator — Thresh shows 0.00V–1.00V, with 10 mV hysteresis.
    • Quantizer — Lowest level is 0, so it rests at Manual.
    • Input monitor — A fifth MOTION page shows each jack's voltage
      (1+0.52V) and an audio level bar.
    • System menu — Encoder rows renamed Enc Test Patt (Developer Mode only)
      and Enc ED/HD Lvl.

    Preset compatibility

    Presets load without errors, but these patches will sound and look different:

    1. CV patches that relied on an offset at 0 V now rest at Manual — raise Manual.
    2. CV and audio patches tuned for 4× Gain need Gain recalibrated.
    3. Audio In patches now respond to loudness rather than waveform voltage.
    4. Slew Limiter Rise/Fall positions need mirroring.
    5. Quantizer's lowest level is now 0, so its steps sit lower than before.

    Requires

    • Flash 1.0.0-rc.69 UF2 (full image — MCU and embedded programs).
    • Official library 1.0.8-rc.1 and community library 1.0.6-rc.1 unchanged.

    Beta testing focus

    Goals: lifecycle/beta/goals/1.0.0-rc.69.yaml.

    1. Rest is Manual — Every input operator with nothing patched leaves the
      parameter exactly at Manual.
    2. CV scale — +1 V at Gain 100% reaches the top; −1 V reaches the bottom.
    3. Audio In — Music at line level gives an instant rise and a fall matching
      the Release readout. Silence returns to Manual.
    4. Per-line — A ramp into Quantizer on P1 gives horizontal bands; Peak Hold
      pulses leave fading trails.
    5. Migration — An rc.66–rc.68 preset with Audio Follower loads as Audio In,
      Ch1+2.

    Report feedback at /instruments/videomancer/beta or via Connect.

    Downloads
  • videomancer/1.0.0-rc.68 227630556a

    lars released this 2026-10-10 02:19:53 +00:00 | 0 commits to main since this release

    Published from monorepo via lzx firmware-publish (2026-10-10T02:19:50.820395+00:00)

    Downloads